PERBANDINGAN KEBERHASILAN PEMASANGAN LARINGEAL MASK
AIRWAY (LMA) UNIQUE PADA UPAYA PERTAMA ANTARA TEKNIK
STANDAR DIGITAL DENGAN TEKNIK JAW TRUST
DI RSM “DR. YAP” YOGYAKARTA
PERBANDINGAN KEBERHASILAN PEMASANGAN LARINGEAL MASK
AIRWAY (LMA) UNIQUE PADA UPAYA PERTAMA ANTARA TEKNIK
STANDAR DIGITAL DENGAN TEKNIK JAW TRUST
DI RSM “DR. YAP” YOGYAKARTA
2017
en
Thesis
text
ABSTRAK
Keberhasilan pemasangan LMA sangat tergantung pada keterampilan petugas dan
kedalaman anestesi yang dapat dinilai dari efek atau komplikasi yang terjadi pada
saat pemasangan. Masih banyak diterapkan berbagai teknik pemasangan LMA
Unique seperti teknik standar digital dan teknik jaw thrust. Berdasarkan teknik
yang digunakan terdapat tindakan yang mengakibatkan pemasangan LMA harus
diulang atau diperbaiki posisi LMA agar kepatenan jalan nafas dapat terjaga.
Penelitian ini bertujuan untuk mengetahui perbandingan keberhasilan pemasangan
LMA Unique pada upaya pertama antara teknik standar digital dengan teknik jaw
thrust di RS Mata “Dr. YAP” Yogyakarta. Penelitian ini merupakan penelitian
eksperimen untuk mengetahui perbandingan keberhasilan pemasangan LMA
Unique pada upaya pertama antara teknik standar digital dengan teknikjaw thrust.
Populasi dalam penelitian adalah semua pasien yang menjalani prosedur bedah
elektif ASA I dan II yang dianestesi umum dengan menggunakan alat bantu napas
LMA Unique. Pengambilan sampel dengan teknik purposivedidapatkan 60 orang.
Analisa data menggunakan Uji Mann-Whitney.Keberhasilan pemasangan LMA
Unique dengan teknik standar digital pada upaya pertama yang dinyatakan
berhasil sebanyak 56,7%. Sementara sebanyak 43,3% mengalami perbaikan..
Keberhasilan pemasangan LMAUnique dengan teknik jaw thrust yang dinyatakan
berhasil sebanyak 90,0%. Sementara yang tidak berhasil hanya 10.0%. Selain itu
terdapat perbedaan keberhasilan pemasangan LMA Uniqueyang signifikan pada
upaya pertama dengan teknik jaw thrust dengan teknik standar digital. Nilai Z
hitung sebesar -2,762 dan nilai signifikansi p-value sebesar 0.006 (p<0.05).
Angka mean rank keberhasilan pemasangan LMA Unique pada upaya pertama
dengan teknik jaw thrust lebih tinggi dibandingkan dengan teknik standar digital.
Terdapat perbedaan keberhasilan pemasangan LMA Unique yang signifikan pada
upaya pertama dengan teknik jaw thrust dengan teknik standar digital.Angka
keberhasilan pemasangan LMA Unique pada upaya pertama dengan teknik jaw
thrust lebih tinggi dibandingkan dengan teknik standar digital.
Kata kunci : LMA, standar digital, jaw thrust
ABSTRAC
The installation success of the LMA is highly dependent on the perpetrators skill
and the depth of anesthesia that can be measured from the effects or
complications that occur during installation. Based on the field practical
experience, various installation techniquess of LMA Unique such as digital
standard techniques and jaw thrust techniques are still widely applied. Based on
the techniques used there are some actions that result the LMA installation must
be repeated or improved in order the patency of the airway can be maintained.
The aim of This study is to know the comparison of the installation success of
LMA Unique at the first effort between digital standard techniques with jaw thrust
techniques at the Eye Hospital of "Dr. YAP" Yogyakarta. This study is an
experimental study to know the comparison installation success of LMA Unique at
the first effort between digital standard techniques with jaw thrust techniques. The
population in this study are all patients who undergo elective surgical procedure
ASA I and II. They are all in general anesthetized using a ventilator LMA Unique.
The techniques that is used to take the sampling is purposive techniques and it is
obtained 60 people. The Data are analyzed using the Mann-Whitney test. 56.7%
are considered succesful at the first effort of the LMA Unique installation with
digital standard techniques. While 43.3% experience improvement. The
installation success of LMA Unique with jaw thrust techniques that is considered
successful are 90.0%. While only 10.0% are fail. In addition, there is a significant
difference of the installation success at the first effort between jaw thrust
techniques with digital standard techniques. This is evidenced by the Z value -
2.762 and the significance value of p-value 0.006 (p <0.05). The Success rate for
LMA Unique installation at the first effort with jaw thrust techniques is higher
than the digital standard techniques. There is a significant difference of the LMA
unique installation success at the first effort between jaw thrust techniques with
digital standard techniques. The Success rate for LMA Unique installation at the
first effort with jaw thrust techniques is higher than the digital standard
techniques.
Keywords: LMA, digital standar, jaw thrust