PERBEDAAN AKURASI PEMERIKSAAN KOLESTEROL
TOTAL SERTA VERIFIKASI METODE TERHADAP JENIS
KALIBRATOR DI BALAI LABORATORIUM KESEHATAN
DAN KALIBRASI YOGYAKARTA
PERBEDAAN AKURASI PEMERIKSAAN KOLESTEROL
TOTAL SERTA VERIFIKASI METODE TERHADAP JENIS
KALIBRATOR DI BALAI LABORATORIUM KESEHATAN
DAN KALIBRASI YOGYAKARTA
2023-04-10
id
Thesis
text
Latar Belakang: Mutu pelayanan didasari penilaian hasil pelayanan laboratorium secara
keseluruhan. Salah satu aspeknya adalah mutu pemeriksaan yang terdapat dua hal pokok,
yaitu ketepatan ( akurasi) dan ketelitian ( presisi). (Hasin, 2016) ISO 15189:2012 klausul
5.6.2.2 tentang bahan pengendalian mutu atau bahan kontrol dijelaskan bahwa
laboratorium harus memilih prosedur pemeriksaan yang telah divalidasi untuk digunakan.
Prosedur pemeriksaan tervalidasi yang digunakan tanpa modifikasi harus dilakukan
verifikasi independen oleh laboratorium.(BSN, 2014) Pada tahun 2021 di BLKK
Yogyakarta menunjukkan 37 % dari 5 pemeriksaan yang sering diminta oleh pelanggan
adalah kadar kolesterol total. (BLKK, 2021)
Tujuan Penelitian: Mengetahui perbedaan akurasi pemeriksaan kolesterol total serta
verifikasi metode terhadap jenis kalibrator di BLKK Yogyakarta.
Metode Penelitian: Jenis penelitian ini adalah Studi komparatif yaitu untuk melihat
perbedaan dua atau lebih situasi atau program yang sejenis.
Hasil Penelitian: Bahan kontrol Trulab N hasil akurasi (%R)97,8; presisi (%CV)2,5; bias
(d%) -0,02; sedangkan kontrol Biorad 1 hasil akurasi (%R)108,0; presisi (%CV)1,7; bias
(d%) 0,08.
Kesimpulan: Ada perbedaan akurasi pemeriksaan kolesterol total dan dengan melihat hasil
akurasi (%R) dan presisi (%CV) disimpulkan bahwa metode bisa digunakan sebagi acuan
dalam pemeriksaan kolesterol total di Balai Laboratorium Kesehatan dan Kalibrasi
Yogyakarta.
Kata Kunci: Kolesterol total, akurasi, verifikasi metode
Background: Service quality is based on an assessment of the results of laboratory services
as a whole. One aspect is the quality of inspection which has two main things, namely
accuracy (accuracy) and accuracy (precision). (Hasin, 2016) ISO 15189:2012 clause
5.6.2.2 on quality control materials or control materials explains that laboratories must
select validated examination procedures for use. Validated examination procedures used
without modification must be carried out independent verification by the laboratory. (BSN,
2014) In 2021 at BLKK Yogyakarta, it showed that 37% of the 5 checks that are often
requested by customers are total cholesterol levels. (BLKK, 2021)
Research Objectives: Knowing the difference in the accuracy of total cholesterol
examination and method verification of the type of calibrator at BLKK Yogyakarta.
Research Methods: This type of research is a comparative study that is to see the
differences of two or more similar situations or programs.
Research Results: Trulab control material N accuracy result (%R)97.8; precision
(%CV)2.5; bias (d%) -0.02; while Biorad control 1 accuracy result (%R)108.0; precision
(%CV)1.7; bias (d%) 0.08.
Conclusion: There is a difference in the accuracy of the total cholesterol test and by
looking at the results of accuracy (%R) and precision (%CV) it is concluded that the method
can be used as a reference in the total cholesterol examination at the Yogyakarta Health
and Calibration Laboratory Center.
Keywords: Total cholesterol, accuracy, verification method